UPSCT2 !!!UPSCT2 NAME SYNOPSIS DESCRIPTION OPTIONS UNATTENDED MODE DIAGNOSTICS BUGS SEE ALSO ---- !!NAME upsct2 - UPS variable administration tool !!SYNOPSIS __upsct2__ ''ups'' __upsct2 -h__ __upsct2 -s__ ''variable'' __[[-u__ ''username''__] [[-p__ ''password''__]__ ''ups'' !!DESCRIPTION __upsct2__ allows you to view and change the read/write variables inside your UPS. It sends commands via the server upsd(8) to your driver, which configures the hardware for you. The list of variables that allow you to change their values is based on the capabilities of your UPS equipment. Not all models support this feature. Typically, cheaper hardware does not support any of them. Run upsct2 with a UPS identifier to see what will work for you. !!OPTIONS -h Display the help message. -s ''variable'' Specify the variable to be changed inside the UPS. For unattended mode such as in shell scripts, use the format VAR=VALUE to specify both the variable and the value, for example: -s HIGHXFER=129 Without this argument, upsct2 will just display the list of the variables and their possible values. Some variables are strings, and can be set to any value within the length limit. Others are enumerated types and can only be set to one of those values. Refer to the list to know what's available in your hardware. -u ''username'' Set the username for the connection to the server. This is optional, and you will be prompted for this when using the -s option if you don't specify -u on the command line. -p ''password'' Set the password to authenticate to the server. This is also optional like -u, and you will be prompted for it if necessary. ''ups'' View or change the settings on this UPS. The format for this option is [[upsname@]hostname[[:port]. !!UNATTENDED MODE If you run this program inside a shell script or similar to set variables, you will need to specify all of the information on the command line. This means using -s VAR=VALUE, -u and -p. Otherwise it will put up a prompt and your program will hang. This is not necessary when displaying the list, as the username and password are not required for read-only mode. !!DIAGNOSTICS upsct2 can't set variables on your UPS unless you provide a valid username and password. If you get upsd.users__(5) has an entry for you, and that the username you are using has permissions to SET variables. !!BUGS The name of this program is misleading, as it does much more than upsct(8). !!SEE ALSO upsd(8), upscmd(8) __Internet resources:__ The NUT (Network UPS Tools) home page: http://www.exploits.org/nut/ NUT mailing list archives and information: http://lists.exploits.org/ ----
7 pages link to
upsct2(8)
:
upscmd(8)
upsd(8)
upslog(8)
upsmon(8)
upsset.cgi(8)
nutupsdrv(8)
Man8u
This page is a man page (or other imported legacy content). We are unable to automatically determine the license status of this page.