fentonups - Driver for Fenton Technologies (Megatec protocol) UPS equipment |
|
|
15 |
!!NOTE |
|
|
16 |
|
|
|
17 |
|
|
|
18 |
This man page only documents the hardware-specific features |
|
|
19 |
of the fentonups driver. For information about the core |
|
|
20 |
driver, see nutupsdrv(8). |
|
|
21 |
!!SUPPORTED HARDWARE |
|
|
22 |
|
|
|
23 |
|
|
|
24 |
fentonups primarily supports Fenton Technologies models such |
|
|
25 |
as the !PowerPal, !PowerPure and !PowerOn lines. Due to the |
|
|
26 |
common heritage of UPS equipment, it also supports other |
|
|
27 |
hardware that also uses the Megatec protocol. |
|
|
28 |
|
|
|
29 |
|
|
|
30 |
At the time of this writing, the !PowerGuard PG-600 and |
|
|
31 |
!PowerCom SMK-800A are recognized and supported. Other |
|
|
32 |
Megatec units should also work, but they will generate a |
|
|
33 |
warning since their battery information is not |
|
|
34 |
known. |
|
|
35 |
!!EXTRA ARGUMENTS |
|
|
36 |
|
|
|
37 |
|
|
|
38 |
This driver does not support any extra values for -x or in |
|
|
39 |
the ups.conf(5). |
|
|
40 |
!!BUGS |
|
|
41 |
|
|
|
42 |
|
|
|
43 |
The battery percentage is derived from the voltage data that |
|
|
44 |
the UPS returns, since the UPS doesn't return that value |
|
|
45 |
directly. On some hardware, the charge will remain at 100% |
|
|
46 |
for a long time and then drops quickly shortly before the |
|
|
47 |
battery runs out. You can confirm from the BATTVOLT readings |
|
|
48 |
that this is a problem with the UPS and not this |
|
|
49 |
driver. |
|
|
50 |
|
|
|
51 |
|
|
|
52 |
Similarly, the float from the charger in some models forces |
|
|
53 |
the battery charge percentage back up to 100% immedately |
|
|
54 |
after the UPS goes back on-line, so you can't tell when it |
|
|
55 |
is really recharged. |
|
|
56 |
!!AUTHOR |
|
|
57 |
|
|
|
58 |
|
|
|
59 |
Russell Kroll |
|
|
60 |
!!SEE ALSO |
|
|
61 |
|
|
|
62 |
|
|
|
63 |
__The core driver:__ |
|
|
64 |
|
|
|
65 |
|
|
|
66 |
nutupsdrv(8) |
|
|
67 |
|
|
|
68 |
|
|
|
69 |
__Internet resources:__ |
|
|
70 |
|
|
|
71 |
|
|
|
72 |
The NUT (Network UPS Tools) home page: |
|
|
73 |
http://www.exploits.org/nut/ |
|
|
74 |
|
|
|
75 |
|
|
|
76 |
NUT mailing list archives and information: |
|
|
77 |
http://lists.exploits.org/ |
|
|
78 |
---- |