Annotated edit history of
ThickNet version 3, including all changes.
View license author blame.
Rev |
Author |
# |
Line |
1 |
LindsayDruett |
1 |
Same physical topology as ThinNet but different.%%% |
|
|
2 |
As Known as 10Base5.%%% |
|
|
3 |
|
|
|
4 |
The proper ThickNet cable is coloured yellow and is around 8mm in diameter.%%% |
|
|
5 |
It is a heavier cable and it's minimum bending radius is no more than 100mm Radius.%%% |
|
|
6 |
Because of these physical constraints, it is not directly terminated on any of the equipment.%%% |
|
|
7 |
|
2 |
LindsayDruett |
8 |
It is terminated via a special cable clamping and termination arrangement knowns as a "Vampire Tap" and a transciever is mounted on the "Vampire Tap", the drop connection to the equipment is done using an AUI cable.%%% |
1 |
LindsayDruett |
9 |
|
3 |
LindsayDruett |
10 |
Each end is terminated with a 50 ohm terminating resistor and __one__ end is earthed.%%% |
|
|
11 |
|
|
|
12 |
The maximum distance is 500 metres. |